...to avoid scrolling this long list, press the 'blackberry' button, select 'Find', input the last 4 digits             

1101

Lead Edge late to the Prefuser 1 Sensor (Q1003).

1103

Lead Edge late to the Prefuser 2 Sensor (Q1004).

1105

Lead Edge late to the Fuser Exit Sensor (Q1005).

1121

An unexpected sheet has arrived at the Prefuser 1 Sensor Q1003.

1123

An unexpected sheet has arrived at the Prefuser Transport 2 Sensor Q1004.

1125

An unexpected sheet has arrived at the Fuser Exit Sensor Q1005.

1201

Lead Edge late to the Upper Duplex Turn Sensor (Q1006).

1202

Unexpected Sheet at the Upper Duplex Turn Sensor (Q1006).

1203

Lead Edge late to the Duplex Horizontal 1 Sensor (Q1007).

1204

Lead Edge late to the Duplex Horizontal 2 Sensor (Q1008).

1205

Lead Edge late to the Duplex Sloping Sensor (Q1009).

1206

Lead Edge late to the Duplex Inverter Entrance Sensor (Q1010).

1207

Lead Edge late to the Duplex Inverter Reversing Sensor (Q1011).

1223

An unexpected sheet has arrived at the Duplex Horizontal 1 Sensor (Q1007).

1224

An unexpected sheet has arrived at the Duplex Horizontal 2 Sensor (Q1008).

1225

An unexpected sheet has arrived at the Duplex Sloping Sensor (Q1009).

1226

An unexpected sheet has arrived at the Duplex Inverter Entrance Sensor (Q1010).

1227

An unexpected sheet has arrived at the Duplex Inverter Reversing Sensor (Q1011).

1301

The Lead Edge of a sheet has arrived outside the jam timing window to the Duplex Bypass Sensor (Q1012) when Duplex is selected.

1302

The Lead Edge of a sheet has arrived outside the jam timing window to the Duplex Bypass Sensor (Q1012) when Duplex is NOT selected.

1303

Lead Edge late to the Velocity Change Entrance Sensor (Q1013).

1323

An unexpected sheet has arrived at the Velocity Change Entrance Sensor (Q1013).

1401

indicates that the Lead Edge of the paper was late to the Output Inverter Exit Sensor (Q1016) from the Output Inverter Entrance Motor (MOT 1024).

1402

Lead Edge late to the Output Inverter Entrance Sensor (Q1014).

1403

Lead Edge Unexpected to the Output Inverter Entrance Sensor (Q1014).

1404

Lead Edge late to the Output Inverter Reversing Sensor (Q1015).

1414

Lead Edge late to the Output Inverter Exit Sensor (Q1016) from the Output Inverter Reversing Motor ( MOT1027).

1415

Trail Edge late to the Output Inverter Exit Sensor (Q1016) from the Output Inverter Reversing Motor ( MOT1027).

1421

An unexpected sheet has arrived at the Output Inverter Exit Sensor (Q1016).

1424

An unexpected sheet has arrived at the Output Inverter Reversing Sensor (Q1015).

3102

Prefuser Transport Motor harness Failure

3103

Prefuser Transport Motor Failed to Start

3104

Prefuser Transport Motor Power Saturation Failure

3105

Prefuser Transport Motor velocity error

3111

Fuser Subsystem Did Not Reach the Ready Temperature

3112

The FSC PWB declared that the AC Voltage is out of range in Print (above 254VAC or below 179VAC).

3122

Fuser Drive Motor Harness Fault

3125

Fuser Drive Motor Failed to Start

3126

Fuser Drive Motor Velocity Error

3127

Fuser Drive Motor Power Saturation Fault

3131

Pressure Roll Cam Motor Windings Fault

3133

Pressure Roll Cam Motor Missing +36VDC

3135

 indicates that the Pressure Roll Limit Sensor (Q1018) or the Pressure Roll Home Sensor (Q1017) has not changed state in the expected time limit after the Pressure Roll Cam Motor (MOT1005) was energized.

3136

Pressure Roll Cam Home and Limit Sensors are indicating blocked.

3142

Donor/External Rolls Cam Motor Missing +36VDC

3146

indicates that the Donor/External Roll Cam Position Sensor 1 (Q1019), Donor/External Roll Cam Position Sensor 2 (Q1021), or the Donor/External Roll Cam Home Sensor (Q1020) has not changed state in the expected time limit after the Donor/External Roll Cam Motor (MOT1006) was energized.

3147

At least two of the following Sensors are indicating blocked:Donor/External Rolls Home Sensor, limit1 or limit2 sensors

3148

Donor/External Rolls Cam Motor Windings Fault

3151

Fuser Exit Transport Motor harness failure

3152

Fuser Exit Transport Motor velocity error

3153

Fuser Exit Transport Motor Power Saturation failure

3154

Fuser Exit Transport Motor failed to start

3167

Fuser RDS Slide Motor Missing +36VDC

3168

Fuser RDS Slide Motor Windings Fault

3171

Fuser RDS Slide Motor Timeout Fault

3172

Fuser RDS Slide Motor Failed to Find Home

3178

Fuser Web Motor Missing +36VDC

3180

Fuser Web Motor Winding Faults

3201

Duplex Gate Motor missing +36VDC

3205

Duplex Gate Motor failed to Find Home

3206

Duplex Gate Motor windings A Failure

3207

Duplex Gate Motor windings B Failure

3209

Duplex Bypass Motor harness Failure

3212

Duplex Bypass Motor velocity error

3213

Duplex Bypass Motor Power Saturation Failure

3217

Upper Duplex Turn Motor harness Failure

3219

Upper Duplex Turn Motor Failed to Start

3220

Upper Duplex Turn Motor velocity error

3221

Upper Duplex Turn Motor Power Saturation Failure

3225

Lower Duplex Turn Motor harness Failure

3227

Lower Duplex Turn Motor Failed to Start

3228

Lower Duplex Turn Motor velocity error

3229

Lower Duplex Turn Motor Power Saturation Failure

3233

Horizontal 1 Motor harness Failure

3235

Horizontal 1 Motor Failed to Start

3236

Horizontal 1 Motor velocity error

3237

Horizontal 1 Motor Power Saturation Failure

3241

Horizontal 2 Motor harness Failure

3243

Horizontal 2 Motor Failed to Start

3244

Horizontal 2 Motor velocity error

3245

Horizontal 2 Motor Power Saturation Failure

3249

Sloping Motor harness Failure

3251

Sloping Motor failed to start

3252

Sloping Motor Velocity Error

3253

Sloping Motor Power Saturation Failure

3257

Duplex Inverter Motor harness failure

3259

Duplex Inverter Motor failed to start

3260

Duplex Inverter Motor Velocity Error

3261

Duplex Inverter Motor Power Saturation Failure

3265

Duplex Inverter Reversing Motor harness Failure

3267

Duplex Inverter Reversing Motor failed to start

3268

Duplex Inverter Reversing Motor velocity error

3269

Duplex Inverter Reversing Motor Power Saturation Failure

3307

Entrance Decurler Home Position Fault

3314

Exit Decurler Home Position Fault

3321

Decurler Transport Motor harness failure

3322

Decurler Transport Motor Failed to Start

3323

Decurler Main Drive Motor velocity error

3324

Decurler Transport Motor Power Saturation Failure

3331

Decurler Main Drive Motor harness Failure

3332

Decurler Main Drive Motor failed to start

3333

Decurler Transport Motor velocity error

3334

Decurler Main Drive Motor Power Saturation Failure

3341

Decurler Cam Motor missing +36VDC

3342

Decurler Entrance Cam Motor windings A Failure

3343

Decurler Entrance Cam Motor windings B Failure

3346

Decurler Exit Cam Motor missing +36VDC

3347

Decurler Exit Cam Motor Windings A Failure

3348

Decurler Exit Cam Motor Windings B Failure

3401

Output Inverter Gate Motor Missing +36VDC

3405

Output Inverter Gate Motor Failed to Find Home

3406

Output Inverter Gate Motor Windings A Failure

3407

Output Inverter Gate Motor Windings B Failure

3411

Output Inverter Entrance Motor Harness Failure

3413

Output Inverter Entrance Motor Failed to Start

3414

Output Inverter Entrance Motor Velocity Error

3415

Output Inverter Entrance Motor Power Saturation Failure

3421

Output Inverter Reversing Motor Harness Failure

3423

Output Inverter Reversing Motor Failed to Start

3424

Output Inverter Reversing Motor Velocity Error

3425

Output Inverter Reversing Motor Power Saturation Failure

3431

Output Inverter Exit Motor Harness Failure

3433

Output Inverter Exit Motor Failed to Start

3434

Output Inverter Exit Motor Velocity Error

3435

Output Inverter Exit Motor Power Saturation Failure

3441

Velocity Change Transport Motor ( MOT1023) harness failure.

3443

VCT Motor Failed to Start

3444

VCT Motor Velocity Error

3445

VCT Motor Power Saturation Failure

4101

Fuser Roll Under Temperature Inboard in Standby

4102

Inboard Fuser Roll Thermistor (RT1001) detected that the temperature went below the Fuser low temperature while in Print.

4103

Fuser Roll Over Temperature Inboard in Standby

4104

Fuser Roll Over Temperature Inboard in Print

4105

Fuser Roll Under Temperature Outboard in Standby

4106

Fuser Roll Under Temperature Outboard in Print

4107

Fuser Roll Over Temperature Outboard in Standby

4108

Fuser Roll Over Temperature Outboard in Print

4109

Pressure Roll Under Temperature in Standby

4110

Pressure Roll Under Temperature in Print

4111

Pressure Roll Over Temperature in Standby

4112

Pressure Roll Over Temperature in Print

4113

Metering Roll Under Temperature in Standby

4114

Metering Roll Under Temperature in Print

4115

Metering Roll Over Temperature in Standby

4116

Metering Roll Over Temperature in Print

4117

External Roll 1 Under Temperature in Standby

4118

External Roll 1 Under Temperature in Print

4119

External Roll 1 Over Temperature in Standby

4120

External Roll 1 Over Temperature in Print

4121

External Roll 2 Under Temperature in Standby

4122

External Roll 2 Under Temperature in Print

4123

External Roll 2 Over Temperature in Standby

4124

External Roll 2 Over Temperature in Print

4130

Pressure Roll Over Temperature in the Enhanced Image Permanence (EIP) Mode

4400

Fuser Low Temperature

4401

Fuser Subsystem Low Temperature: External Roll 1

4402

Fuser Subsystem Low Temperature: External Roll 2

4403

Fuser Subsystem Low Temperature: Fuser Roll

4404

The Fuser Subsystem temperature for Pressure Roll went to a not READY condition for greater than the time-out interval after being in a READY condition.

4405

The fuser temperature has not reached the READY condition within the time-out interval during a mode switch.

5001

code is displayed when the Fuser is in the enhanced permanence mode. This condition is determined by settings in the Stock Library.

5002

code is displayed if the machine has not been cycled-up for a set period of time. The lamps are switched off to conserve energy.

5003

Fuser Fluid Low

5005

Fuser Fluid Depleted

5007

Fuser Web Low

5008

Fuser Web Depleted

5009

Fuser AC Line Voltage Out of Range in Standby Fault

5013

Fuser Drawer Open in Standby

5014

Fuser Drawer Open in Print

5102

Sheet on Prefuser 1 Sensor

5103

Sheet between Prefuser 1 and 2 Sensors

5104

Sheet on Prefuser 2 Sensor

5105

Sheet between Prefuser 2 and Fuser Exit Sensors

5106

Sheet on Fuser Exit Sensor

5107

Sheet between Fuser Exit and Duplex Bypass Sensors

5108

Sheet between Fuser Exit and Upper Duplex Turn Sensors

5201

Sheet detected on the Upper Duplex Turn Sensor

5202

Sheet between Upper Duplex Turn and Horizontal 1 Sensors

5203

Sheet on Duplex Horizontal 1 Sensor

5204

Sheet between the Horizontal 1 and 2 Sensors

5205

Sheet on Duplex Horizontal 2 Sensor

5206

Sheet between the Horizontal 2 and Sloping Sensors

5207

Sheet on Sloping Sensor

5208

Sheet between Sloping and Duplex Inverter Entrance Sensors

5209

Sheet on Duplex Inverter Entrance Sensor

5210

Sheet between Duplex Inverter Entrance and Reversing Sensors

5211

Sheet on Duplex Inverter Reversing Sensor

5212

Sheet between Duplex Inverter Reversing and Reg Transport Entrance Sensors

5213

Side-2 Sheet on Reg Transport Entrance Sensor

5301

Sheet on Duplex Bypass Sensor

5302

Sheet between Duplex Bypass and VCT Entrance Sensors

5303

Sheet on VCT Entrance Sensor

5304

Sheet between VCT Entrance and the Output Inverter Exit Sensors

5305

Sheet between the VCT Entrance and Output Inverter Entrance Sensors

5401

Sheet on Output Inverter Exit Sensor from VCT Entrance Sensor

5402

Sheet on Output Inverter Entrance Sensor

5403

Sheet between the Output Inverter Entrance and Reversing Sensors

5404

Sheet on Output Inverter Reversing Sensor

5405

Sheet between Output Inverter Reversing and Exit Sensors

5406

Sheet on the Output Inverter Exit Sensor from Reversing Sensor

5801

Fuser Temperature Control Disabled

5802

Print Engine in Low Power Mode

 