...to avoid scrolling this long list, press the 'blackberry' button, select 'Find', input the last 4 digits
|
1101 |
Lead Edge late to the Prefuser 1 Sensor (Q1003). |
|
|
1103 |
Lead Edge late to the Prefuser 2 Sensor (Q1004). |
|
|
1105 |
Lead Edge late to the Fuser Exit Sensor (Q1005). |
|
|
1121 |
An unexpected sheet has arrived at the Prefuser 1 Sensor Q1003. |
|
|
1123 |
An unexpected sheet has arrived at the Prefuser Transport 2 Sensor Q1004. |
|
|
1125 |
An unexpected sheet has arrived at the Fuser Exit Sensor Q1005. |
|
|
1201 |
Lead Edge late to the Upper Duplex Turn Sensor (Q1006). |
|
|
1202 |
Unexpected Sheet at the Upper Duplex Turn Sensor (Q1006). |
|
|
1203 |
Lead Edge late to the Duplex Horizontal 1 Sensor (Q1007). |
|
|
1204 |
Lead Edge late to the Duplex Horizontal 2 Sensor (Q1008). |
|
|
1205 |
Lead Edge late to the Duplex Sloping Sensor (Q1009). |
|
|
1206 |
Lead Edge late to the Duplex Inverter Entrance Sensor (Q1010). |
|
|
1207 |
Lead Edge late to the Duplex Inverter Reversing Sensor (Q1011). |
|
|
1223 |
An unexpected sheet has arrived at the Duplex Horizontal 1 Sensor (Q1007). |
|
|
1224 |
An unexpected sheet has arrived at the Duplex Horizontal 2 Sensor (Q1008). |
|
|
1225 |
An unexpected sheet has arrived at the Duplex Sloping Sensor (Q1009). |
|
|
1226 |
An unexpected sheet has arrived at the Duplex Inverter Entrance Sensor (Q1010). |
|
|
1227 |
An unexpected sheet has arrived at the Duplex Inverter Reversing Sensor (Q1011). |
|
|
1301 |
The Lead Edge of a sheet has arrived outside the jam timing window to the Duplex Bypass Sensor (Q1012) when Duplex is selected. |
|
|
1302 |
The Lead Edge of a sheet has arrived outside the jam timing window to the Duplex Bypass Sensor (Q1012) when Duplex is NOT selected. |
|
|
1303 |
Lead Edge late to the Velocity Change Entrance Sensor (Q1013). |
|
|
1323 |
An unexpected sheet has arrived at the Velocity Change Entrance Sensor (Q1013). |
|
|
1401 |
indicates that the Lead Edge of the paper was late to the Output Inverter Exit Sensor (Q1016) from the Output Inverter Entrance Motor (MOT 1024). |
|
|
1402 |
Lead Edge late to the Output Inverter Entrance Sensor (Q1014). |
|
|
1403 |
Lead Edge Unexpected to the Output Inverter Entrance Sensor (Q1014). |
|
|
1404 |
Lead Edge late to the Output Inverter Reversing Sensor (Q1015). |
|
|
1414 |
Lead Edge late to the Output Inverter Exit Sensor (Q1016) from the Output Inverter Reversing Motor ( MOT1027). |
|
|
1415 |
Trail Edge late to the Output Inverter Exit Sensor (Q1016) from the Output Inverter Reversing Motor ( MOT1027). |
|
|
1421 |
An unexpected sheet has arrived at the Output Inverter Exit Sensor (Q1016). |
|
|
1424 |
An unexpected sheet has arrived at the Output Inverter Reversing Sensor (Q1015). |
|
|
3102 |
Prefuser Transport Motor harness Failure |
|
|
3103 |
Prefuser Transport Motor Failed to Start |
|
|
3104 |
Prefuser Transport Motor Power Saturation Failure |
|
|
3105 |
Prefuser Transport Motor velocity error |
|
|
3111 |
Fuser Subsystem Did Not Reach the Ready Temperature |
|
|
3112 |
The FSC PWB declared that the AC Voltage is out of range in Print (above 254VAC or below 179VAC). |
|
|
3122 |
Fuser Drive Motor Harness Fault |
|
|
3125 |
Fuser Drive Motor Failed to Start |
|
|
3126 |
Fuser Drive Motor Velocity Error |
|
|
3127 |
Fuser Drive Motor Power Saturation Fault |
|
|
3131 |
Pressure Roll Cam Motor Windings Fault |
|
|
3133 |
Pressure Roll Cam Motor Missing +36VDC |
|
|
3135 |
indicates that the Pressure Roll Limit Sensor (Q1018) or the Pressure Roll Home Sensor (Q1017) has not changed state in the expected time limit after the Pressure Roll Cam Motor (MOT1005) was energized. |
|
|
3136 |
Pressure Roll Cam Home and Limit Sensors are indicating blocked. |
|
|
3142 |
Donor/External Rolls Cam Motor Missing +36VDC |
|
|
3146 |
indicates that the Donor/External Roll Cam Position Sensor 1 (Q1019), Donor/External Roll Cam Position Sensor 2 (Q1021), or the Donor/External Roll Cam Home Sensor (Q1020) has not changed state in the expected time limit after the Donor/External Roll Cam Motor (MOT1006) was energized. |
|
|
3147 |
At least two of the following Sensors are indicating blocked:Donor/External Rolls Home Sensor, limit1 or limit2 sensors |
|
|
3148 |
Donor/External Rolls Cam Motor Windings Fault |
|
|
3151 |
Fuser Exit Transport Motor harness failure |
|
|
3152 |
Fuser Exit Transport Motor velocity error |
|
|
3153 |
Fuser Exit Transport Motor Power Saturation failure |
|
|
3154 |
Fuser Exit Transport Motor failed to start |
|
|
3167 |
Fuser RDS Slide Motor Missing +36VDC |
|
|
3168 |
Fuser RDS Slide Motor Windings Fault |
|
|
3171 |
Fuser RDS Slide Motor Timeout Fault |
|
|
3172 |
Fuser RDS Slide Motor Failed to Find Home |
|
|
3178 |
Fuser Web Motor Missing +36VDC |
|
|
3180 |
Fuser Web Motor Winding Faults |
|
|
3201 |
Duplex Gate Motor missing +36VDC |
|
|
3205 |
Duplex Gate Motor failed to Find Home |
|
|
3206 |
Duplex Gate Motor windings A Failure |
|
|
3207 |
Duplex Gate Motor windings B Failure |
|
|
3209 |
Duplex Bypass Motor harness Failure |
|
|
3212 |
Duplex Bypass Motor velocity error |
|
|
3213 |
Duplex Bypass Motor Power Saturation Failure |
|
|
3217 |
Upper Duplex Turn Motor harness Failure |
|
|
3219 |
Upper Duplex Turn Motor Failed to Start |
|
|
3220 |
Upper Duplex Turn Motor velocity error |
|
|
3221 |
Upper Duplex Turn Motor Power Saturation Failure |
|
|
3225 |
Lower Duplex Turn Motor harness Failure |
|
|
3227 |
Lower Duplex Turn Motor Failed to Start |
|
|
3228 |
Lower Duplex Turn Motor velocity error |
|
|
|
Lower Duplex Turn Motor Power Saturation Failure |
|
|
3233 |
Horizontal 1 Motor harness Failure |
|
|
3235 |
Horizontal 1 Motor Failed to Start |
|
|
3236 |
Horizontal 1 Motor velocity error |
|
|
3237 |
Horizontal 1 Motor Power Saturation Failure |
|
|
3241 |
Horizontal 2 Motor harness Failure |
|
|
3243 |
Horizontal 2 Motor Failed to Start |
|
|
3244 |
Horizontal 2 Motor velocity error |
|
|
3245 |
Horizontal 2 Motor Power Saturation Failure |
|
|
3249 |
Sloping Motor harness Failure |
|
|
3251 |
Sloping Motor failed to start |
|
|
3252 |
Sloping Motor Velocity Error |
|
|
3253 |
Sloping Motor Power Saturation Failure |
|
|
3257 |
Duplex Inverter Motor harness failure |
|
|
3259 |
Duplex Inverter Motor failed to start |
|
|
3260 |
Duplex Inverter Motor Velocity Error |
|
|
3261 |
Duplex Inverter Motor Power Saturation Failure |
|
|
3265 |
Duplex Inverter Reversing Motor harness Failure |
|
|
3267 |
Duplex Inverter Reversing Motor failed to start |
|
|
3268 |
Duplex Inverter Reversing Motor velocity error |
|
|
3269 |
Duplex Inverter Reversing Motor Power Saturation Failure |
|
|
3307 |
Entrance Decurler Home Position Fault |
|
|
3314 |
Exit Decurler Home Position Fault |
|
|
3321 |
Decurler Transport Motor harness failure |
|
|
3322 |
Decurler Transport Motor Failed to Start |
|
|
3323 |
Decurler Main Drive Motor velocity error |
|
|
3324 |
Decurler Transport Motor Power Saturation Failure |
|
|
3331 |
Decurler Main Drive Motor harness Failure |
|
|
3332 |
Decurler Main Drive Motor failed to start |
|
|
3333 |
Decurler Transport Motor velocity error |
|
|
3334 |
Decurler |
|
|
3341 |
Decurler Cam Motor missing +36VDC |
|
|
3342 |
Decurler Entrance Cam Motor windings A Failure |
|
|
3343 |
Decurler Entrance Cam Motor windings B Failure |
|
|
3346 |
Decurler Exit Cam Motor missing +36VDC |
|
|
3347 |
Decurler Exit Cam Motor Windings A Failure |
|
|
3348 |
Decurler Exit Cam Motor Windings B Failure |
|
|
3401 |
Output Inverter Gate Motor Missing +36VDC |
|
|
3405 |
Output Inverter Gate Motor Failed to Find Home |
|
|
3406 |
Output Inverter Gate Motor Windings A Failure |
|
|
3407 |
Output Inverter Gate Motor Windings B Failure |
|
|
3411 |
Output Inverter Entrance Motor Harness Failure |
|
|
3413 |
Output Inverter Entrance Motor Failed to Start |
|
|
3414 |
Output Inverter Entrance Motor Velocity Error |
|
|
3415 |
Output Inverter Entrance Motor Power Saturation Failure |
|
|
3421 |
Output Inverter Reversing Motor Harness Failure |
|
|
3423 |
Output Inverter Reversing Motor Failed to Start |
|
|
3424 |
Output Inverter Reversing Motor Velocity Error |
|
|
3425 |
Output Inverter Reversing Motor Power Saturation Failure |
|
|
3431 |
Output Inverter Exit Motor Harness Failure |
|
|
3433 |
Output Inverter Exit Motor Failed to Start |
|
|
3434 |
Output Inverter Exit Motor Velocity Error |
|
|
3435 |
Output Inverter Exit Motor Power Saturation Failure |
|
|
3441 |
Velocity Change Transport Motor ( MOT1023) harness failure. |
|
|
3443 |
VCT Motor Failed to Start |
|
|
3444 |
VCT Motor Velocity Error |
|
|
3445 |
VCT Motor Power Saturation Failure |
|
|
4101 |
Fuser Roll Under Temperature Inboard in Standby |
|
|
4102 |
Inboard Fuser Roll Thermistor (RT1001) detected that the temperature went below the Fuser low temperature while in Print. |
|
|
4103 |
Fuser Roll Over Temperature Inboard in Standby |
|
|
4104 |
Fuser Roll Over Temperature Inboard in Print |
|
|
4105 |
Fuser Roll Under Temperature Outboard in Standby |
|
|
4106 |
Fuser Roll Under Temperature Outboard in Print |
|
|
4107 |
Fuser Roll Over Temperature Outboard in Standby |
|
|
4108 |
Fuser Roll Over Temperature Outboard in Print |
|
|
4109 |
Pressure Roll Under Temperature in Standby |
|
|
4110 |
Pressure Roll Under Temperature in Print |
|
|
4111 |
Pressure Roll Over Temperature in Standby |
|
|
4112 |
Pressure Roll Over Temperature in Print |
|
|
4113 |
Metering Roll Under Temperature in Standby |
|
|
4114 |
Metering Roll Under Temperature in Print |
|
|
4115 |
Metering Roll Over Temperature in Standby |
|
|
4116 |
Metering Roll Over Temperature in Print |
|
|
4117 |
External Roll 1 Under Temperature in Standby |
|
|
4118 |
External Roll 1 Under Temperature in Print |
|
|
4119 |
External Roll 1 Over Temperature in Standby |
|
|
4120 |
External Roll 1 Over Temperature in Print |
|
|
4121 |
External Roll 2 Under Temperature in Standby |
|
|
4122 |
External Roll 2 Under Temperature in Print |
|
|
4123 |
External Roll 2 Over Temperature in Standby |
|
|
4124 |
External Roll 2 Over Temperature in Print |
|
|
4130 |
Pressure Roll Over Temperature in the Enhanced Image Permanence (EIP) Mode |
|
|
4400 |
Fuser Low Temperature |
|
|
4401 |
Fuser Subsystem Low Temperature: External Roll 1 |
|
|
4402 |
Fuser Subsystem Low Temperature: External Roll 2 |
|
|
4403 |
Fuser Subsystem Low Temperature: Fuser Roll |
|
|
4404 |
The Fuser Subsystem temperature for Pressure Roll went to a not READY condition for greater than the time-out interval after being in a READY condition. |
|
|
4405 |
The fuser temperature has not reached the READY condition within the time-out interval during a mode switch. |
|
|
5001 |
code is displayed when the Fuser is in the enhanced permanence mode. This condition is determined by settings in the Stock Library. |
|
|
5002 |
code is displayed if the machine has not been cycled-up for a set period of time. The lamps are switched off to conserve energy. |
|
|
5003 |
Fuser Fluid Low |
|
|
5005 |
Fuser Fluid Depleted |
|
|
5007 |
Fuser Web Low |
|
|
5008 |
Fuser Web Depleted |
|
|
5009 |
Fuser AC Line Voltage Out of Range in Standby Fault |
|
|
5013 |
Fuser Drawer Open in Standby |
|
|
5014 |
Fuser Drawer Open in Print |
|
|
5102 |
Sheet on Prefuser 1 Sensor |
|
|
5103 |
Sheet between Prefuser 1 and 2 Sensors |
|
|
5104 |
Sheet on Prefuser 2 Sensor |
|
|
5105 |
Sheet between Prefuser 2 and Fuser Exit Sensors |
|
|
5106 |
Sheet on Fuser Exit Sensor |
|
|
5107 |
Sheet between Fuser Exit and Duplex Bypass Sensors |
|
|
5108 |
Sheet between Fuser Exit and Upper Duplex Turn Sensors |
|
|
5201 |
Sheet detected on the Upper Duplex Turn Sensor |
|
|
5202 |
Sheet between Upper Duplex Turn and Horizontal 1 Sensors |
|
|
5203 |
Sheet on Duplex Horizontal 1 Sensor |
|
|
5204 |
Sheet between the Horizontal 1 and 2 Sensors |
|
|
5205 |
Sheet on Duplex Horizontal 2 Sensor |
|
|
5206 |
Sheet between the Horizontal 2 and Sloping Sensors |
|
|
5207 |
Sheet on Sloping Sensor |
|
|
5208 |
Sheet between Sloping and Duplex Inverter Entrance Sensors |
|
|
5209 |
Sheet on Duplex Inverter Entrance Sensor |
|
|
5210 |
Sheet between Duplex Inverter Entrance and Reversing Sensors |
|
|
5211 |
Sheet on Duplex Inverter Reversing Sensor |
|
|
5212 |
Sheet between Duplex Inverter Reversing and Reg Transport Entrance Sensors |
|
|
5213 |
Side-2 Sheet on Reg Transport Entrance Sensor |
|
|
5301 |
Sheet on Duplex Bypass Sensor |
|
|
5302 |
Sheet between Duplex Bypass and VCT Entrance Sensors |
|
|
5303 |
Sheet on VCT Entrance Sensor |
|
|
5304 |
Sheet between VCT Entrance and the Output Inverter Exit Sensors |
|
|
5305 |
Sheet between the VCT Entrance and Output Inverter Entrance Sensors |
|
|
5401 |
Sheet on Output Inverter Exit Sensor from VCT Entrance Sensor |
|
|
5402 |
Sheet on Output Inverter Entrance Sensor |
|
|
5403 |
Sheet between the Output Inverter Entrance and Reversing Sensors |
|
|
5404 |
Sheet on Output Inverter Reversing Sensor |
|
|
5405 |
Sheet between Output Inverter Reversing and Exit Sensors |
|
|
5406 |
Sheet on the Output Inverter Exit Sensor from Reversing Sensor |
|
|
5801 |
Fuser Temperature Control Disabled |
|
|
5802 |
Print Engine in Low Power Mode |