1101 |
LE Late to the Prefuser 1 Sensor |
|
1103 |
LE Late to the Prefuser 2 Sensor |
|
1105 |
LE Late to the Fuser Exit Sensor |
|
1121 |
Unexpected Sheet at the Prefuser 1 Sensor |
|
1123 |
Unexpected Sheet at the Prefuser 2 Sensor |
|
1125 |
Unexpected Sheet at the Fuser Exit Sensor |
|
1201 |
LE Late to the Upper Duplex Turn Sensor |
|
1202 |
Unexpected Sheet at the Upper Duplex Turn Sensor |
|
1203 |
LE Late to the Horizontal 1 Sensor |
|
1204 |
LE Late to the Horizontal 2 Sensor |
|
1205 |
LE Late to the Sloping Sensor |
|
1206 |
LE Late to the Duplex Inverter Entrance Sensor |
|
1207 |
LE Late to the Duplex Inverter Reversing Sensor |
|
1223 |
Unexpected Sheet at the Horizontal 1 Sensor |
|
1224 |
Unexpected Sheet at the Horizontal 2 Sensor |
|
1225 |
Unexpected Sheet at the Duplex Sloping Sensor |
|
1226 |
Unexpected Sheet at the Duplex Inverter Entrance Sensor |
|
1227 |
Unexpected Sheet at the Duplex Inverting Reversing Sensor |
|
1301 |
LE late to the Duplex Bypass Sensor |
|
1302 |
LE Unexpected to the Duplex Bypass Sensor |
|
1303 |
LE Late to the VCT Entrance Sensor |
|
1323 |
Unexpected Sheet at the VCT Entrance Sensor |
|
1401 |
LE Late to the Output Inverter Exit Sensor from Bypass Path |
|
1402 |
LE Late to the Output Inverter Entrance Sensor |
|
1403 |
LE Unexpected to the Output Inverter Entrance Sensor |
|
1404 |
LE Late to the Output Inverter Reversing Sensor |
|
1414 |
LE Late to the Output Inverter Exit Sensor |
|
1415 |
TE Late to the Output Inverter Exit Sensor |
|
1421 |
Unexpected Sheet at the Output Inverter Exit Sensor |
|
1424 |
Unexpected Sheet at the Output Inverter Reversing Sensor |
|
1430 |
ILS Sheet Sensor LE Timing Error |
|
3102 |
Prefuser Transport Motor harness Failure |
|
3103 |
Prefuser Transport Motor Failed to Start |
|
3104 |
Prefuser Transport Motor Power Saturation Failure |
|
3105 |
Prefuser Transport Motor velocity error |
|
3111 |
Fuser Subsystem Did Not Reach the Ready Temperature |
|
3112 |
Fuser AC Line Voltage Out of Range in Print |
|
3122 |
Fuser Drive Motor Harness Fault |
|
3125 |
Fuser Drive Motor Failed to Start |
|
3126 |
Fuser Drive Motor Velocity Error |
|
3127 |
Fuser Drive Motor Power Saturation Fault |
|
3131 |
Pressure Roll Cam Motor Windings Fault |
|
3133 |
Pressure Roll Cam Motor Missing +36VDC |
|
3135 |
Pressure Roll Cam Motor Timeout Fault |
|
3136 |
Pressure Roll Cam Sensor Fault |
|
3142 |
Donor/External Rolls Cam Motor Missing +36VDC |
|
3146 |
Donor/External Cam Motor Timeout Fault |
|
3147 |
Donor/External Cam Sensor Fault |
|
3148 |
Donor/External Rolls Cam Motor Windings Fault |
|
3151 |
Fuser Exit Transport Motor harness failure |
|
3152 |
Fuser Exit Transport Motor velocity error |
|
3153 |
Fuser Exit Transport Motor Power Saturation failure |
|
3154 |
Fuser Exit Transport Motor failed to start |
|
3167 |
Fuser RDS Slide Motor Missing +36VDC |
|
3168 |
Fuser RDS Slide Motor Windings Fault |
|
3171 |
Fuser RDS Slide Motor Timeout Fault |
|
3172 |
Fuser RDS Slide Motor Failed to Find Home |
|
3178 |
Fuser Web Motor Missing +36VDC |
|
3180 |
Fuser Web Motor Winding Faults |
|
3201 |
Duplex Gate Motor missing +36VDC |
|
3205 |
Duplex Gate Motor failed to Find Home |
|
3206 |
Duplex Gate Motor windings A Failure |
|
3207 |
Duplex Gate Motor windings B Failure |
|
3209 |
Duplex Bypass Motor harness Failure |
|
3211 |
Duplex Bypass Motor failed to start |
|
3212 |
Duplex Bypass Motor velocity error |
|
3213 |
Duplex Bypass Motor Power Saturation Failure |
|
3217 |
Upper Duplex Turn Motor harness Failure |
|
3219 |
Upper Duplex Turn Motor Failed to Start |
|
3220 |
Upper Duplex Turn Motor velocity error |
|
3221 |
Upper Duplex Turn Motor Power Saturation Failure |
|
3225 |
Lower Duplex Turn Motor harness Failure |
|
3227 |
Lower Duplex Turn Motor Failed to Start |
|
3228 |
Lower Duplex Turn Motor velocity error |
|
3229 |
Lower Duplex Turn Motor Power Saturation Failure |
|
3233 |
Horizontal 1 Motor harness Failure |
|
3235 |
Horizontal 1 Motor Failed to Start |
|
3236 |
Horizontal 1 Motor velocity error |
|
3237 |
Horizontal 1 Motor Power Saturation Failure |
|
3241 |
Horizontal 2 Motor harness Failure |
|
3243 |
Horizontal 2 Motor Failed to Start |
|
3244 |
Horizontal 2 Motor velocity error |
|
3245 |
Horizontal 2 Motor Power Saturation Failure |
|
3249 |
Sloping Motor harness Failure |
|
3251 |
Sloping Motor failed to start |
|
3252 |
Sloping Motor Velocity Error |
|
3253 |
Sloping Motor Power Saturation Failure |
|
3257 |
Duplex Inverter Motor harness failure |
|
3259 |
Duplex Inverter Motor failed to start |
|
3260 |
Duplex Inverter Motor Velocity Error |
|
3261 |
Duplex Inverter Motor Power Saturation Failure |
|
3265 |
Duplex Inverter Reversing Motor harness Failure |
|
3267 |
Duplex Inverter Reversing Motor failed to start |
|
3268 |
Duplex Inverter Reversing Motor velocity error |
|
3269 |
Duplex Inverter Reversing Motor Power Saturation Failure |
|
3307 |
Entrance Decurler Home Position Fault |
|
3314 |
Exit Decurler Home Position Fault |
|
3321 |
Decurler Transport Motor harness failure |
|
3322 |
Decurler Transport Motor Failed to Start |
|
3323 |
Decurler Main Drive Motor velocity error |
|
3324 |
Decurler Transport Motor Power Saturation Failure |
|
3331 |
Decurler Main Drive Motor harness Failure |
|
3332 |
Decurler Main Drive Motor failed to start |
|
3333 |
Decurler Transport Motor velocity error |
|
3334 |
Decurler Main Drive Motor Power Saturation Failure |
|
3341 |
Decurler Cam Motor missing +36VDC |
|
3342 |
Decurler Entrance Cam Motor windings A Failure |
|
3343 |
Decurler Entrance Cam Motor windings B Failure |
|
3346 |
Decurler Exit Cam Motor missing +36VDC |
|
3347 |
Decurler Exit Cam Motor Windings A Failure |
|
3348 |
Decurler Exit Cam Motor Windings B Failure |
|
3401 |
Output Inverter Gate Motor Missing +36VDC |
|
3405 |
Output Inverter Gate Motor Failed to Find Home |
|
3406 |
Output Inverter Gate Motor Windings A Failure |
|
3407 |
Output Inverter Gate Motor Windings B Failure |
|
3411 |
Output Inverter Entrance Motor Harness Failure |
|
3413 |
Output Inverter Entrance Motor Failed to Start |
|
3414 |
Output Inverter Entrance Motor Velocity Error |
|
3415 |
Output Inverter Entrance Motor Power Saturation Failure |
|
3421 |
Output Inverter Reversing Motor Harness Failure |
|
3423 |
Output Inverter Reversing Motor Failed to Start |
|
3424 |
Output Inverter Reversing Motor Velocity Error |
|
3425 |
Output Inverter Reversing Motor Power Saturation Failure |
|
3431 |
Output Inverter Exit Motor Harness Failure |
|
3433 |
Output Inverter Exit Motor Failed to Start |
|
3434 |
Output Inverter Exit Motor Velocity Error |
|
3435 |
Output Inverter Exit Motor Power Saturation Failure |
|
3441 |
VCT Motor harness Failure |
|
3443 |
VCT Motor Failed to Start |
|
3444 |
VCT Motor Velocity Error |
|
3445 |
VCT Motor Power Saturation Failure |
|
3450 |
ILS - Color Patch Timeout Fault |
|
3461 |
Horizontal Transport 1 VC Motor Harness Failure |
|
3462 |
Horizontal 1 Motor Failed to Start |
|
3463 |
Horizontal 1 VC Motor Velocity Error |
|
3464 |
Horizontal 1 VC Motor Power Saturation Failure |
|
3471 |
Decurler Transport Motor Harness Failure |
|
3472 |
Decurler Transport Motor Failed to Start |
|
3473 |
Decurler Transport Motor Velocity Error |
|
3474 |
Decurler Transport Motor Power Saturation Failure |
|
4101 |
Fuser Roll Under Temperature Inboard in Standby |
|
4102 |
Fuser Roll Under Temperature Inboard in Print |
|
4103 |
Fuser Roll Over Temperature Inboard in Standby |
|
4104 |
Fuser Roll Over Temperature Inboard in Print |
|
4105 |
Fuser Roll Under Temperature Outboard in Standby |
|
4106 |
Fuser Roll Under Temperature Outboard in Print |
|
4107 |
Fuser Roll Over Temperature Outboard in Standby |
|
4108 |
Fuser Roll Over Temperature Outboard in Print |
|
4109 |
Pressure Roll Under Temperature in Standby |
|
4110 |
Pressure Roll Under Temperature in Print |
|
4111 |
Pressure Roll Over Temperature in Standby |
|
4112 |
Pressure Roll Over Temperature in Print |
|
4113 |
Metering Roll Under Temperature in Standby |
|
4114 |
Metering Roll Under Temperature in Print |
|
4115 |
Metering Roll Over Temperature in Standby |
|
4116 |
Metering Roll Over Temperature in Print |
|
4117 |
External Roll 1 Under Temperature in Standby |
|
4118 |
External Roll 1 Under Temperature in Print |
|
4119 |
External Roll 1 Over Temperature in Standby |
|
4120 |
External Roll 1 Over Temperature in Print |
|
4121 |
External Roll 2 Under Temperature in Standby |
|
4122 |
External Roll 2 Under Temperature in Print |
|
4123 |
External Roll 2 Over Temperature in Standby |
|
4124 |
External Roll 2 Over Temperature in Print |
|
4130 |
Pressure Roll Over Temperature in the Enhanced Image Permanence (EIP) Mode |
|
4400 |
Fuser Low Temperature |
|
4401 |
Fuser Subsystem Low Temperature: External Roll 1 |
|
4402 |
Fuser Subsystem Low Temperature: External Roll 2 |
|
4403 |
Fuser Subsystem Low Temperature: Fuser Roll |
|
4404 |
Fuser Subsystem Low Temperature: Pressure Roll |
|
4405 |
Fuser Low Temperature: Metering Roll |
|
5001 |
Enhanced Permanence Mode is On |
|
5002 |
Fuser Warming Up |
|
5003 |
Fuser Fluid Low |
|
5005 |
Fuser Fluid Depleted |
|
5007 |
Fuser Web Low |
|
5008 |
Fuser Web Depleted |
|
5009 |
Fuser AC Line Voltage Out of Range in Standby Fault |
|
5013 |
Fuser Drawer Open in Standby |
|
5014 |
Fuser Drawer Open in Print |
|
5100 |
Contact Arc Measurement Sheet In Fuser |
|
5102 |
Sheet on Prefuser 1 Sensor |
|
5103 |
Sheet between Prefuser 1 and 2 Sensors |
|
5104 |
Sheet on Prefuser 2 Sensor |
|
5105 |
Sheet between Prefuser 2 and Fuser Exit Sensors |
|
5106 |
Sheet on Fuser Exit Sensor |
|
5107 |
Sheet between Fuser Exit and Duplex Bypass Sensors |
|
5108 |
Sheet between Fuser Exit and Upper Duplex Turn Sensors |
|
5201 |
Sheet detected on the Upper Duplex Turn Sensor |
|
5202 |
Sheet between Upper Duplex Turn and Horizontal 1 Sensors |
|
5203 |
Sheet on Duplex Horizontal 1 Sensor |
|
5204 |
Sheet between the Horizontal 1 and 2 Sensors |
|
5205 |
Sheet on Duplex Horizontal 2 Sensor |
|
5206 |
Sheet between the Horizontal 2 and Sloping Sensors |
|
5207 |
Sheet on Sloping Sensor |
|
5208 |
Sheet between Sloping and Duplex Inverter Entrance Sensors |
|
5209 |
Sheet on Duplex Inverter Entrance Sensor |
|
5210 |
Sheet between Duplex Inverter Entrance and Reversing Sensors |
|
5211 |
Sheet on Duplex Inverter Reversing Sensor |
|
5212 |
Sheet between Duplex Inverter Reversing and Reg Transport Entrance Sensors |
|
5213 |
Side-2 Sheet on Reg Transport Entrance Sensor |
|
5214 |
Duplex Return Nip Release Open |
|
5215 |
Duplex Return Nip Release Closed |
|
5301 |
Sheet on Duplex Bypass Sensor |
|
5302 |
Sheet between Duplex Bypass and VCT Entrance Sensors |
|
5303 |
Sheet on VCT Entrance Sensor |
|
5304 |
Sheet between VCT Entrance and the Output Inverter Exit Sensors |
|
5305 |
Sheet between the VCT Entrance and Output Inverter Entrance Sensors |
|
5401 |
Sheet on Output Inverter Exit Sensor from VCT Entrance Sensor |
|
5402 |
Sheet on Output Inverter Entrance Sensor |
|
5403 |
Sheet between the Output Inverter Entrance and Reversing Sensors |
|
5404 |
Sheet on Output Inverter Reversing Sensor |
|
5405 |
Sheet between Output Inverter Reversing and Exit Sensors |
|
5406 |
Sheet on the Output Inverter Exit Sensor from Reversing Sensor |
|
5801 |
Fuser Temperature Control Disabled |
|
5802 |
Print Engine in Low Power Mode |
|
7000 |
Fuser Air System Checkout Procedure |
|
7001 |
Fuser Roll Run Heater |
|
7002 |
Fuser Roll Standby Heater |
|
7003 |
External Roll 1 11inch Heater |
|
7004 |
External Roll 1 14inch Heater |
|
7005 |
External Roll 2 11 inch Heater |
|
7006 |
External Roll 2 14inch Heater |
|
7007 |
Pressure Roll Heater |
|
7008 |
Metering Roll Heater |
|
7009 |
Phase A Monitoring Fault |
|
7010 |
Phase B Monitoring Fault |
|
7011 |
Phase C Monitoring Fault |
|
7012 |
Phase A and B Monitoring Fault |
|
7013 |
Phase A and C Monitoring Fault |
|
7014 |
Phase B and C Monitoring Fault |
|
7015 |
Phase A, B, and C Monitoring Fault |
|
7016 |
+24VDC Interlock/Thermostat Failure |
|
7017 |
Pressure Roll Cooling System Checkout Procedure |