CODE

DESCRIPTION

 

PROGRAM

101

Sheet on photoreceptor (Lead Edge at paper on photoreceptor sensor S7) in A4

Common

102

Sheet on photoreceptor (Lead Edge at paper on photoreceptor sensor S7) in A3

Common

201

High voltage power supply arc detected.

Common

202

AC voltage out of range while running.

Common

203

Photoreceptor end of life

 

Common

211

Patch generator failure

 

Common

212

IRD failure

 

Common

213

ESV failure

 

Common

215

Toner dispense failure

 

Common

220

Too long between belt holes

 

Common

221

Ozone blower air flow failure

 

Common

222

Too short time between belt holes

 

Common

320

Developer bias #1 out of range

 

Common

321

Developer bias #2 out of range.

 

Common

322

Cleaner voltage out of range

 

Common

323

Reclaim roll bias voltage out of range

 

Common

324

Waste roll bias voltage out of range

 

Common

325

Charge voltage out of range

 

Common

326

Transfer current out of range

 

Common

327

Detack current out of range

 

Common

328

Pre-clean current out of range

 

Common

329

AC voltage out of range

 

Common

330

Charge 2 current out of range

 

Common

331

Charge 0 voltage out of range

 

Common

332

Failure to complete cycle up convergence after a power up.

Common

353

Failure to converge charge fault

 

Common

354

Failure to set toner concentration fault

Common

355

Failure to set Patch Gen in dC951.

 

Common

356

Failure to converge charge in TC setup for dC951

Common

360

Failure to complete AmCal Setup in dC951

Common

361

AmCal out of range in dC951.

 

Common

400

HLC dC951 Failed to Converge

 

Sorrento

402

HLC Toner Concentration Too High

 

Sorrento

403

HLC Dry Ink Empty

 

Sorrento

405

HLC TC Sensor Reading Too High

 

Sorrento

406

HLC ETACS LED Intensity Out of Range

Sorrento

408

HLC Recharge Dicorotron Shield to PR Voltage Slope Out of Range

Sorrento

409

HLC ETACS Sensor Offset Voltage Out of Range

Sorrento

410

HLC ETACS Readings Out of Range and Recharge Target at Upper Limit

Sorrento

411

HLC PR Belt Residual Voltage Too High

Sorrento

412

HLC ETACS Average Diffuse Clean Belt Reading Out of Range

Sorrento

413

HLC Recharge Convergence Timed Out

Sorrento

414

HLC ETACS Readings Out of Range and Image Bar Intensity at Upper Limit

Sorrento

415

HLC ETACS Readings Out of Range and Mag Roll Bias at Upper Limit

Sorrento

416

HLC ESV at Maximum

 

Sorrento

417

HLC TC Too Low While Retoning

 

Sorrento

418

HLC HSD Power Supply Overload

 

Sorrento

419

HLC ETACS Not Capable of Reading Solid Area Patch

Sorrento

422

HLC Developer Donor Roll Motor at Maximum Power

Sorrento

423

HLC Developer Mag Roll Motor at Maximum Power

Sorrento

424

HLC Waste Developer Container Full

 

Sorrento

426

HLC ETACS Diffuse Clean Belt out of range

Sorrento

428

HLC TC Sensor Interface PWB Comparator Fault

Sorrento

430

HLC TC Sensor Open Circuit

 

Sorrento

431

HLC TC Sensor Toner Concentration Count Too Low

Sorrento

432

HLC TC Sensor Temperature Counts Too High

Sorrento

433

Cleaner Waste Dry Ink Container Missing in Production

Sorrento

434

HLC ETACS Readings Out of Range and Cleaning Field at Upper Limit

Sorrento

438

HLC Diffuse ETACS Reading Too Low During Calibration

Sorrento

444

Ozone Filters Full

 

Sorrento

445

Waste Dry Ink Container Full

 

Sorrento

446

Cleaner Waste Dry Ink Container Missing in Standby

Sorrento

447

Cleaner Waste Dry Ink Filter Full

 

Sorrento

450

HLC Cycle Up Convergence Failed

 

Sorrento

451

HLC Recharge Voltage Signature Uniformity Fault

Sorrento

481

HLC PQA Long Timeout Failure

 

Sorrento

482

HLC PQA Short Timeout Failure

 

Sorrento

483

HLC ETACS Readings Out of Range and Recharge Target at Lower Limit

Sorrento

484

HLC ETACS Readings Out of Range and Image Bar Intensity at Lower Limit

Sorrento

485

HLC ETACS Readings Out of Range and Vmag at Lower Limit

Sorrento

486

HLC ESV at Minimum

 

Sorrento

487

HLC Developer Mag Roll Motor Velocity Error

Sorrento

488

HLC Developer Donor Roll Motor Failed to Start

Sorrento

489

HLC Developer Mag Roll Motor Failed to Start

Sorrento

492

HLC ETACS LED intensity out of range warning

Sorrento

493

HLC TC Sensor Interface PWB Overpower Fault

Sorrento

494

HLC TC Sensor Interface PWB A to D Fault

Sorrento

496

HLC TC Sensor Temperature Counts Too Low

Sorrento

497

HLC TC Sensor Temperature Too High

Sorrento

498

HLC Image Bar Exposure at Maximum

Sorrento

499

HLC Image Bar Exposure at Minimum

Sorrento

600

HLC Recharge Shield Voltage at Maximum

Sorrento

601

HLC Recharge Shield Voltage at Minimum

Sorrento

602

HLC ETACS Readings Out of Range and Cleaning Field at Lower Limit

Sorrento

603

HLC Cleaning Field at Minimum

 

Sorrento

604

HLC Mag Roll Bias at Maximum

 

Sorrento

605

HLC Mag Roll Bias at Minimum

 

Sorrento

606

HLC Recharge Target at Maximum

 

Sorrento

607

HLC Developer Donor Roll Motor Velocity Error

Sorrento

609

HLC TC Sensor Temperature Too Low

Sorrento

610

HLC ETACS Failed to Converge

 

Sorrento

611

HLC High Voltage Arc Detected

 

Sorrento

612

HLC Recharge 2 Shield Voltage Out of Range

Sorrento

613

HLC Pretransfer Shield Current Out of Range

Sorrento

614

HLC AC Wire Voltage Out of Range

 

Sorrento

615

HLC Recharge 2 Shield Current Out of Range

Sorrento

616

HLC Recharge 1 Shield Current Out of Range

Sorrento

617

HLC Pretransfer Shield Voltage Out of Range

Sorrento

618

HLC AC Wire Voltage at Limit

 

Sorrento

619

HLC AC Wire Voltage Failed to converge

Sorrento

620

HLC ETACS Diffuse Clean Belt Signature Uniformity Fault

Sorrento

621

HLC ETACS Specular Clean Belt Signature Uniformity Fault

Sorrento

622

HLC Waste Developer Container Full or Missing In Production

Sorrento

623

HLC Recharge Target at Minimum

 

Sorrento

624

HLC TC Adjustment During Skipped Pitch

Sorrento

625

HLC Developer Wire Cleaning During Skipped Pitch

Sorrento

626

HLC ETACS Convergence During Skipped Pitch

Sorrento

627

HLC Adjustment During Skipped Pitch Failed

Sorrento

628

HLC Purge of Aged Toner During Skipped Pitch

Sorrento

629

HLC Dry Ink Dispense Rate Too Low

 

Sorrento

630

HLC TC High Too Long While Detoning

Sorrento

631

HLC HSD Power Supply Missing 36 Volts

Sorrento

632

HLC Cleaning Field at Maximum

 

Sorrento

633

HLC Dispense Auger Motor Winding A Fault

Sorrento

634

HLC Dispense Auger Motor Winding B Fault

Sorrento

635

HLC Dispense Auger Motor Missing +36V

Sorrento

636

HCN Post Wire Cleaning ETACS Convergence During Skipped Pitch

Sorrento

637

HCN No Belt Hole Signal From LRIC

 

Sorrento

639

HLC PR Residual Voltage Too Different from Previous Reading

Sorrento

642

HLC Developer Auger Magnet Not Detected

Sorrento

643

HLC Dry Ink Low

 

Sorrento

644

HLC Developer Near End of Life

 

Sorrento

645

HLC Long PQA Running

 

Sorrento

646

HLC Long PQA Pending

 

Sorrento

647

HLC Specular Clean Belt Average Below Minimum

Sorrento

648

HLC Short PQA Running

 

Sorrento

649

HLC Short PQA Pending

 

Sorrento

650

HLC CCU Memory Read Error

 

Sorrento

651

HLC CCU Memory invalid entry

 

Sorrento

652

HLC CCU toner color not valid

 

Sorrento

653

HLC Adjusting Print Quality

 

Sorrento

 
Make a Free Website with Yola.