B0-C8 Mark detection PWB cannot read the sheet ID correctly
B1-C8 Mark detection PWB cannot read the sheet ID correctly
B1-C9 Printer not ready for printing/paper exhausting within the correct time.
B2-E0 Mechanism control PWB to mark detection PWB communication error.
B2-E2 Mark detection PWB cannot read the registration mark correctly.
B3-E8 Transfer speed correction amount exceeds the allowable range.
B3-E9 Main-scan write position correction amount exceeds the specified range in the mark detection PWB, i.e. paper speed is not consistent.
B3-EA Sub-scan write position correction amount exceeds the specified range in the mark detection PWB, i.e. paper speed is not consistent.
C0-00 Controller data parity error.
C0-01 Controller address parity error.
C0-02 There is a break in the video interface path, i.e. between the NLP-K PWB and the mechanism control PWB.
C0-03 The IOT has not acknowledged a transfer request from the controller within the specified time frame. A timeout has occurred.
C0-05 The sensor located on the NLP-K PWB has detected that the temperature inside the Stampa PC is too high, i.e. over 52 degrees C.
C0-06 The sensor located on the power control unit PWB has detected that the temperature near the power control unit PWB is too high, i.e. over 52 degrees C.
C0-0D A command submitted to the IOT has not received a response in the allowed time frame, resulting in a timeout. This is an IOT problem.
C0-0E A read command from the microcode to the IOT has failed.
C0-0E IOT read command time-out
C0-10 The controller has run out of memory (as a result of a memory leak, for example) and it is therefore not possible to send a skip command to the IOT.
C0-11 The number of skip commands requested by the printer has reached the limit set by the controller.
C0-12 The video transfer has not occurred in the allowed time frame, resulting in a timeout.
C0-13 The upstream printer has printed the front page but the downstream printer has not yet printed the back page. The downstream controller has detected a mismatch between the expected sheet ID and the received sheet ID. This error occurs only when the downstream printer is already aligned and no longer searching for the tandem mark.
C0-14 An abnormal page sequence has been detected during the alignment process.
C0-20 The NLP-K PWB is at the wrong FPGA version.
C0-20 Hardware error (APEX chip)
C0-21 One of the sensors on the power control unit PWB or the NLP-K PWB detected a temperature of over 57 degrees C.
C0-21 Hardware error (temperature sensor chip)
C0-22 There is a problem with CAN bus 1 (internal CAN bus).
C0-22 Hardware error (CAN bus#1)
C0-23 There is a problem with CAN bus 2 (external CAN bus, PLB). The external CAN bus includes the PLB bus and implements synchronisation of a duplex line.
C0-23 Hardware error (CAN bus#2)
C0-24 There is a problem with the communication between the NLP-K PWB and the power control unit PWB.
C0-24 Hardware error (power control unit PWB)
C0-25 An IOT command that was submitted has not been acknowledged in the allowed timeframe.
C0-26 There is a problem with the IOT power state.
C0-26 Hardware error (IOT power)
C0-27 There is a problem with the NLP-K onboard diagnostics.
C0-27 Hardware error (diagnostic)
C0-28 One of the sensors on the power control unit PWB or the NLP-K PWB has detected a temperature of over 52 degrees C.
C0-28 Hardware error (temperature alarm)
C0-40 If more than one of the errors that follow occur, this error code appears to announce multiple errors:
C2-00 There is a problem with the communication protocol on the dual-port RAM.
C2-01 NLPi PWB command time-out
C2-20 CAN1 transmission error.
C2-21 CAN1 receipt error.
C2-22 There is a problem with the power control unit PWB.
C2-23 This is an error from the communication module between the PC and the NLP-K PWB.
C2-24 This is an error from the communication module between the PC and the NLP-K PWB.
C2-25 This is an error from the communication module between the NLP-K PWB and the power control unit PWB.
C2-26 An IOT command has not been acknowledged by the NLP microcode.
C2-27 There is a bad response from the NLP-K onboard temperature sensor.
C2-28 There is a communication problem between the attention light and the NLP-K PWB.
C2-29 The attention light temperature is too high.
 