76-80 The LED print head assembly overheats.
76-81 Image data quantity sent by the mechanism control PWB is not the image data quantity received by the LED print head assembly.
76-81 A LED print head fault has been detected.
76-81 LED print head assembly not installed.
7D-A8 Temperature/humidity sensor detects that temperature inside the printer is outside the specified range.
7D-A9 Temperature/humidity sensor detects that humidity inside the printer is outside the specified range.
7D-AB The fuse on the sensor circuit PWB has blown.
7D-AC Mechanism control PWB internal control error.
7D-AD Input output PWB to sensor circuit PWB communication error.
7D-AE Fuse on the motor driver PWB has blown.
7D-AF Fuse on the input output PWB has blown.
7D-F4 Input output PWB to motor driver PWB communications error.
7D-F5 Unit power control PWB does not reply.
7D-F5 Unit power control PWB is not connected.
7D-F5 Fuser cooling blower is not controlled.
7D-F5 A communication error occurs on the unit power control PWB.
8C-01 Mechanism control PWB RAM error.
8C-02 Dual port RAM error.
8C-B4 An error has occurred in the non volatile RAM on the mechanism control PWB during power-on.
8D-B1 Mechanism control PWB detects a video data parity error.
8D-B2 Mechanism control PWB detects a video data empty error.
8D-B3 Mechanism control PWB detects a video data overrun error.
8D-B5 Mechanism control PWB detects a head video data error.
8D-B6 Mechanism control PWB detects a FIFO data remaining error.
90-51 Pre-charger current or voltage falls outside the specified range after pre-charger on.
90-58 Grid voltage calculated by the process control is above the specified value
90-59 Grid voltage calculated by the process control is below the specified value
90-8C Pre-charger 2 cleaner home position sensor is not actuated within the pre-set time after pre-charger 2 cleaner motor start.
90-8C Pre-charger 2 cleaner home position sensor remains actuated beyond the pre-set time after pre-charger 2 cleaner motor start.
90-8D Pre-charger 2 cleaner motor over current detected.
90-8E Pre-charger 1 cleaner home position sensor is not actuated within the pre-set time after pre-charger 1 cleaner motor start.
90-8E Pre-charger 1 cleaner home position sensor remains actuated beyond the pre-set time after pre-charger 1 cleaner motor start.
90-8F Pre-charger 1 cleaner motor over current detected.
91-50 The corona current or wire voltage is outside the specified range after transfer charger on.
91-8A Transfer charger cleaner home position switch is not actuated within the pre-set time after transfer charger cleaner motor start.
91-8A Transfer charger cleaner home position switch remains actuated beyond the pre-set time after transfer charger cleaner motor start.
91-8B Transfer charger cleaner motor over current detected.
94-53 Mechanism control PWB detects abnormal developer bias output.
95-56 Difference between drum surface potential sensors 1 and 2 output voltage and target voltage exceeds the specified value
95-57 Difference between the output voltages of the drum surface potential sensors exceeds the specified value.

 

 