091-311

CC Cleaner Motor Fail

During Home Position Detection or Cleaning, CC Cleaner Position Sensor voltage level does not change in a spec time.

091-312

CC HVPS Fail

CC HVPS has failed.

091-313

CRUM ASIC Communication Fail

091-320 CC Wire Break

091-320

CC Wire Break

Charge Corotron Wire is broken.

091-400

Bottle Standard Near Full

The replacement date for Waste Toner Bottle (regular) is near.

091-401

Drum Near End

The replacement date of Drum Unit is near. (Warning)

091-410

Bottle Option Near Full

The replacement date of Waste Toner Bottle (option) is near.

091-910

Bottle Standard Not in Position

Waste Toner Bottle (regular) is improperly installed.

091-911

Bottle Standard Full

Waste Toner Bottle (regular) is full.

091-912

Drum Not in Position

Drum is improperly installed.

091-913

Drum End

Drum should be replace.

091-914

Drum CRUM Communication Fail

A communication failure with Drum CRUM

091-915

Drum CRUM Data Broken Fail

Mismatch between data written onto CRUM and data read.

091-916

Drum CRUM Data Mismatch Fail

CRUM Authentication Area Data differs.

091-921

Drum CRUM Not in Position

Drum CRUM is disconnected.

091-930

Bottle Option Not in Position

Waste Toner Bottle (option) is improperly installed.

091-931

Bottle Option Full

Waste Toner Bottle (option) is full.

092-607

VGS Fail

Vgrid used to obtain Target VH is out of range (400~853). Or the two levels of Vgrid: high (VG_OUT+50) and low (VG_OUT-50) used to charge Grid are reversed (in Mini-Setup).

092-608

VH3 Fail

The measured value of VH (VH3) of Grid charged with tentative Vgrid is far larger than the predictive value (>30) (in Mini-Setup).

092-609

LDS Fail

LD light qty used to obtain Target Potential is out of range (300~1023). Or when two levels of LD light qty: high (LD_OUT+60) and low (LD_OUT-60) are used for exposure, a potential difference is smaller (ÅÖ15) (in Mini-Setup).

092-610

VM3 Fail

The difference between measured and predictive values of ADC Patch potential (VM3), the last item of Mini-Setup is larger (>30) (in Mini-Setup).

092-611

VHVM Fail

One of VGS Fail, VH3 Fail, LDS Fail, and VM3 Fail has occurred.

092-612

VM ADC Fail

The result of ADC Patch Potential measured during a job is out of range. (This occurs during a job.)

092-651

ADC Sensor Fail

The output read by ADC Sensor from the clean Photoreceptor surface is out of range (100~1000) (in Mini-Setup).

092-652

ADC Patch Fail

The measured ADC Patch density is light. (Over 75% of Vclean)

092-656

ATC Out Fail

ATC Sensor output is out of range (150~1022).

092-660

ATC Amplitude Fail

The amplitude of ATC Sensor output is smaller (<10).

092-661

Temperature Sensor Fail

Environment Sensor temperature output is out of range (140~896).

092-662

Humidity Sensor Fail

Environment Sensor humidity output is out of range (30~607).

092-663

Minimum Setup ADC Fail

The two levels of ADC Patch density created in Mini-Setup: high (LD_OUT+60) and low (LD_OUT-60) are reversed.

092-664

ATC Average Warning

Fail Code 092-664 requires no service.

093-311

Dispense Broken

Dispense Motor has failed.

093-320

Deve Motor Fail

Deve Motor rotation error

093-400

Toner Near Empty

The replacement date of Toner Cartridge is near.

093-405

Dispense Near Broken

Dispense Motor may be broken.

093-912

Toner Empty

Toner Cartridge and Reserve Tank are empty.

093-924

Toner CRUM Comm Fail

A communication failure with Toner Cartridge CRUM

093-925

Toner CRUM Data Broken Fail

Mismatch between data written onto Toner CRUM and data read.

093-926

Toner CRUM Data Mismatch Fail

Toner CRUM Authentication Area Data is different.

093-931

Toner Filling Interrupt

Toner Dispense Mode (at M/C installation) is not complete.

093-932

Cartridge Exchange Time Over