091-311 |
CC Cleaner Motor Fail |
During Home Position Detection or Cleaning, CC Cleaner Position Sensor voltage level does not change in a spec time. |
|
091-312 |
CC HVPS Fail |
CC HVPS has failed. |
|
091-313 |
CRUM ASIC Communication Fail |
091-320 CC Wire Break |
|
091-320 |
CC Wire Break |
Charge Corotron Wire is broken. |
|
091-400 |
Bottle Standard Near Full |
The replacement date for Waste Toner Bottle (regular) is near. |
|
091-401 |
Drum Near End |
The replacement date of Drum Unit is near. (Warning) |
|
091-410 |
Bottle Option Near Full |
The replacement date of Waste Toner Bottle (option) is near. |
|
091-910 |
Bottle Standard Not in Position |
Waste Toner Bottle (regular) is improperly installed. |
|
091-911 |
Bottle Standard Full |
Waste Toner Bottle (regular) is full. |
|
091-912 |
Drum Not in Position |
Drum is improperly installed. |
|
091-913 |
Drum End |
Drum should be replace. |
|
091-914 |
Drum CRUM Communication Fail |
A communication failure with Drum CRUM |
|
091-915 |
Drum CRUM Data Broken Fail |
Mismatch between data written onto CRUM and data read. |
|
091-916 |
Drum CRUM Data Mismatch Fail |
CRUM Authentication Area Data differs. |
|
091-921 |
Drum CRUM Not in Position |
Drum CRUM is disconnected. |
|
091-930 |
Bottle Option Not in Position |
Waste Toner Bottle (option) is improperly installed. |
|
091-931 |
Bottle Option Full |
Waste Toner Bottle (option) is full. |
|
092-607 |
VGS Fail |
Vgrid used to obtain Target VH is out of range (400~853). Or the two levels of Vgrid: high (VG_OUT+50) and low (VG_OUT-50) used to charge Grid are reversed (in Mini-Setup). |
|
092-608 |
VH3 Fail |
The measured value of VH (VH3) of Grid charged with tentative Vgrid is far larger than the predictive value (>30) (in Mini-Setup). |
|
092-609 |
LDS Fail |
LD light qty used to obtain Target Potential is out of range (300~1023). Or when two levels of LD light qty: high (LD_OUT+60) and low (LD_OUT-60) are used for exposure, a potential difference is smaller (ÅÖ15) (in Mini-Setup). |
|
092-610 |
VM3 Fail |
The difference between measured and predictive values of ADC Patch potential (VM3), the last item of Mini-Setup is larger (>30) (in Mini-Setup). |
|
092-611 |
VHVM Fail |
One of VGS Fail, VH3 Fail, LDS Fail, and VM3 Fail has occurred. |
|
092-612 |
VM ADC Fail |
The result of ADC Patch Potential measured during a job is out of range. (This occurs during a job.) |
|
092-651 |
ADC Sensor Fail |
The output read by ADC Sensor from the clean Photoreceptor surface is out of range (100~1000) (in Mini-Setup). |
|
092-652 |
ADC Patch Fail |
The measured ADC Patch density is light. (Over 75% of Vclean) |
|
092-656 |
ATC Out Fail |
ATC Sensor output is out of range (150~1022). |
|
092-660 |
ATC Amplitude Fail |
The amplitude of ATC Sensor output is smaller (<10). |
|
092-661 |
Temperature Sensor Fail |
Environment Sensor temperature output is out of range (140~896). |
|
092-662 |
Humidity Sensor Fail |
Environment Sensor humidity output is out of range (30~607). |
|
092-663 |
Minimum Setup ADC Fail |
The two levels of ADC Patch density created in Mini-Setup: high (LD_OUT+60) and low (LD_OUT-60) are reversed. |
|
092-664 |
ATC Average Warning |
Fail Code 092-664 requires no service. |
|
093-311 |
Dispense Broken |
Dispense Motor has failed. |
|
093-320 |
Deve Motor Fail |
Deve Motor rotation error |
|
093-400 |
Toner Near Empty |
The replacement date of Toner Cartridge is near. |
|
093-405 |
Dispense Near Broken |
Dispense Motor may be broken. |
|
093-912 |
Toner Empty |
Toner Cartridge and Reserve Tank are empty. |
|
093-924 |
Toner CRUM Comm Fail |
A communication failure with Toner Cartridge CRUM |
|
093-925 |
Toner CRUM Data Broken Fail |
Mismatch between data written onto Toner CRUM and data read. |
|
093-926 |
Toner CRUM Data Mismatch Fail |
Toner CRUM Authentication Area Data is different. |
|
093-931 |
Toner Filling Interrupt |
Toner Dispense Mode (at M/C installation) is not complete. |
|
093-932 |
Cartridge Exchange Time Over |