...to avoid scrolling this long list, press the 'blackberry' button, select 'Find', input the last 3 digits...
|
071-100 |
Tray 1 Miss Pre Feed Jam |
Pre Feed Sensor 1 is not turned ON a spec time after the start of feed from Tray 1. |
|
071-101 |
Tray 1 Miss Feed Jam |
Feed Out Sensor 1 is not turned ON a spec time after the start of feed from Tray 1. |
|
071-104 |
Pre Regi Sensor ON Jam (Tray 1) |
Paper from Tray 1 does not turn ON Pre Regi Sensor within a spec time. |
|
071-105 |
Regi |
Paper from Tray 1 does not turn ON Regi Sensor within a spec time. |
|
071-210 |
Tray 1 Lift Up Fail |
Tray 1 Level Sensor does not turn ON a spec time after the tray is inserted. |
|
072-100 |
Tray 2 Miss Pre Feed Jam |
Pre Feed Sensor 2 is not turned ON a spec time after the start of feed from Tray 2. |
|
072-101 |
Tray 2 Miss Feed Jam |
Feed Out Sensor 2 is not turned ON a spec time after the start of feed from Tray 2. |
|
072-104 |
Pre Regi Sensor ON Jam (Tray 2) |
Paper from Tray 2 does not turn ON Pre Regi Sensor within a spec time. |
|
072-105 |
Regi |
Paper from Tray 2 does not turn ON Regi Sensor within a spec time. |
|
072-210 |
Tray 2 Lift Up Fail |
Tray 2 Level Sensor does not turn ON a spec time after the tray is inserted. |
|
073-100 |
Tray 3 Miss Pre Feed Jam |
Pre Feed Sensor 3 is not turned ON a spec time after the start of feed from Tray 3. |
|
073-101 |
Tray 3 Miss Feed Jam |
Feed Out Sensor 3 is not turned ON a spec time after the start of feed from Tray 3. |
|
073-102 |
Feed Out Sensor 1 ON Jam (Tray 3) |
Paper from Tray 3 does not turn ON Feed Out Sensor 1 within a spec time. |
|
073-104 |
Pre Regi Sensor ON Jam (Tray 3) |
Paper from Tray 3 does not turn ON Pre Regi Sensor within a spec time. |
|
073-105 |
Regi |
Paper from Tray 3 does not turn ON Regi Sensor within a spec time. |
|
073-210 |
Tray 3 Lift Up Fail |
Tray 3 Level Sensor does not turn ON a spec time after the tray is inserted. |
|
074-100 |
Tray 4 Miss Pre Feed Jam |
Pre Feed Sensor 4 is not turned ON a spec time after the start of feed from Tray 4. |
|
074-101 |
Tray 4 Miss Feed Jam |
Feed Out Sensor 4 is not turned ON a spec time after the start of feed from Tray 4. |
|
074-102 |
Feed Out Sensor 1 ON Jam (Tray 4) |
Paper from Tray 4 does not turn ON Feed Out Sensor 1 within a spec time. |
|
074-104 |
Pre Regi Sensor ON Jam (Tray 4) |
Paper from Tray 4 does not turn ON Pre Regi Sensor within a spec time. |
|
074-105 |
Regi |
Paper from Tray 4 does not turn ON Regi Sensor within a spec time. |
|
074-210 |
Tray 4 Lift Up Fail |
Tray 4 Level Sensor does not turn ON a spec time after the tray is inserted. |
|
075-100 |
MSI Miss Feed Jam |
MSI Pre Feed Sensor is not turned ON a spec time after the start of feed from MSI. |
|
075-101 |
MSI Feed Out Sensor ON Jam |
MSI Feed Out Sensor is not turned ON a spec time after the start of feed from MSI. |
|
075-109 |
Pre Regi Sensor ON Jam (MSI) |
Paper from MSI does not turn ON Pre Regi Sensor within a spec time. |
|
075-135 |
Regi |
Paper from MSI does not turn ON Regi Sensor within a spec time. |
|
075-210 |
MSI Lift Up Fail |
MSI Lift Up Sensor does not turn ON a spec time after MSI starts lifting up. |
|
075-211 |
MSI Lift Down Fail |
MSI Lift Down Sensor does not turn ON a spec time after MSI starts lowering. |
|
077-102 |
Trans Path Sensor 1 ON Jam (Tray 2) |
Paper from Tray 2 does not turn ON Trans Path Sensor 1 within a spec time. |
|
077-103 |
Fuser Exit Sensor OFF Jam (Straight) |
In Straight Output Mode, Fuser Exit Sensor does not turn OFF within a spec time. |
|
077-106 |
Fuser Exit Sensor ON Jam |
Fuser Exit Sensor does not turn ON a spec time after Regi Motor ON. |
|
077-107 |
Fuser Exit Sensor OFF Jam (Invert) |
In Invert Output Mode, Fuser Exit Sensor does not turn OFF within a spec time. |
|
077-109 |
Fuser Exit Sensor OFF Jam (Non Invert) |
In Non-Invert Mode, IOT Exit Sensor is not turned OFF within a spec time. |
|
077-111 |
IOT Exit Sensor ON Jam (Invert) |
In Invert Output Mode, IOT Exit Sensor does not turn ON in a spec time. |
|
077-113 |
IOT Exit Sensor OFF Jam (Non Invert) |
In Non-Invert Mode, IOT Exit Sensor is not turned OFF within a spec time. |
|
077-115 |
IOT Exit Sensor OFF Jam (Invert) |
In Invert Output Mode, IOT Exit Sensor does not turn OFF within a spec time. |
|
077-118 |
Pre Regi Sensor ON Jam (Duplex) |
Paper through Duplex does not turn ON Pre Regi Sensor within a spec time. |
|
077-123 |
Regi |
Paper through Duplex does not turn ON Regi Sensor within a spec time. |
|
077-128 |
Invert In Sensor ON Jam |
Invert In Sensor does not turn ON a spec time after Fuser Exit Sensor ON. |
|
077-129 |
Duplex In Sensor ON Jam |
Duplex In Sensor does not turn ON a spec time after the start of invert. |
|
077-130 |
Duplex Out Sensor ON Jam |
Duplex Out Sensor does not turn ON a spec time after Duplex In Sensor ON. |
|
077-132 |
Invert In Sensor OFF Jam |
Invert In Sensor does not turn OFF within a spec time. |
|
077-300 |
Front Cover Interlock Open |
Front Cover is open. 077-301 L/H Cover Interlock Open |
|
077-304 |
MSI Cover Interlock Open |
MSI Cover Interlock is open. |
|
077-305 |
Trans Path Interlock Open |
Horizontal Transport is slid out. |
|
077-306 |
Marking Drawer Open |
Marking Drawer is slid out. |
|
077-307 |
Duplex Drawer Open |
Duplex Drawer is slid out. |
|
077-311 |
Invert Release Fail |
Release Home Sensor voltage level does not change a spec time after Release Motor ON. |
|
077-330 |
Feeder Communication Fail |
HCF and MCU PWB cannot communicate. |
|
077-600 |
Side Regi Home Fail |
Side Regi Home Sensor voltage level does not change a spec time after Side Regi Move Move Motor ON. |
|
077-601 |
Side Regi Fail |
• Side Regi Sensor turns ON 40ms after Pre Regi Sensor ON. |
|
077-909 |
IOT Static Jam |
At |
|
077-967 |
Paper Kind Mismatch (APS Job) |
Paper type selected is different from the type of paper installed. |
|
077-968 |
Paper Kind Mismatch (Job Continue) |
The type of paper in Tray is changed. |
|
078-100 |
Pre Regi Sensor ON Jam (Tray 6) |
Paper from Tray 6 does not turn ON Pre Regi Sensor within a spec time. |
|
078-101 |
Tray 6 Feed Out |
Tray 6 Feed Out Sensor does not turn ON a spec time after the start of feed. |
|
078-102 |
Regi |
Paper from Tray 6 does not turn ON Regi Sensor within a spec time. |
|
078-103 |
HCF Exit Sensor ON Jam |
HCF Exit Sensor does not turn ON a spec time (which depends on the tray) after the Feed Out Sensor of an appropriate one of the trays in HCF turns ON. |
|
078-105 |
Tray 5 (HCF MSI) Pre Feed Sensor ON Jam |
MSI Pre Feed Sensor is not turned ON a spec time after the start of MSI Feed. |
|
078-106 |
Tray 6 Pre Feed Sensor ON Jam |
Tray 6 Pre Feed Sensor is not turned ON a spec time after the start of Tray 6 Feed. |
|
078-110 |
Pre Regi Sensor ON Jam (Tray 5) (HCF MSI) |
Paper from Tray 5 (HCF MSI) does not turn ON Pre Regi Sensor within a spec time. |
|
078-111 |
Regi Sensor ON Jam (Tray 5) (HCF MSI) |
Paper from Tray 5 (HCF MSI) does not turn ON Regi Sensor within a spec time. |
|
078-120 |
Tray 5 (HCF MSI) Feed Out Sensor ON Jam |
MSI Feed Out Sensor is not turned ON a spec time after the start of MSI Feed. |
|
078-150 |
Pre Regi Sensor ON Jam (Tray 7) |
Paper from Tray 7 does not turn ON Pre Regi Sensor within a spec time. |
|
078-120 |
Tray 5 (HCF MSI) Feed Out Sensor ON Jam |
MSI Feed Out Sensor is not turned ON a spec time after the start of MSI Feed. |
|
078-150 |
Pre Regi Sensor ON Jam (Tray 7) |
Paper from Tray 7 does not turn ON Pre Regi Sensor within a spec time. |
|
078-151 |
Tray 7 Feed Out |
Tray 7 Feed Out Sensor is not turned ON a spec time after the start of feed. |
|
078-152 |
Regi |
Paper from Tray 7 does not turn ON Regi Sensor within a spec time. |
|
078-156 |
Tray 7 Pre Feed Sensor ON Jam |
Tray 7 Pre Feed Sensor is not turned ON a spec time after the start of Tray 7 Feed. |
|
078-210 |
Tray 6 Lift Up Fail |
Tray 6 Level Sensor does not turn ON a spec time after Tray 6 is inserted. |
|
078-211 |
Tray 7 Lift Up Fail |
Tray 7 Level Sensor is not turned ON a spec time after Tray 7 is inserted. |
|
078-213 |
Tray 5(HCF MSI) Lift Up Fail |
Tray 5 (HCF MSI) Lift Up Sensor does not turn ON a spec time after the tray starts lifting up. |
|
078-214 |
Tray 5(HCF MSI) Lift Down Fail |
Tray 5 (HCF MSI) Lift Down Sensor does not turn ON a spec time after the tray starts lowering. |
|
078-300 |
HCF Transport Interlock Open |
HCF Transport Interlock is open. |
|
078-302 |
Tray 5(HCF MSI) Interlock Open |
Tray 5(HCF MSI) Interlock is open. |
|
078-900 |
Tray 6 Feed Out Sensor Static Jam |
At |
|
078-901 |
Tray 7 Feed Out Sensor Static Jam |
At |
|
078-902 |
Tray 5(HCF MSI) Feed Out Sensor Static Jam |
At |
|
078-903 |
Tray 5(HCF MSI) Pre Feed Sensor Static Jam |
At |
|
078-904 |
HCF Exit Sensor Static Jam |
At |